Federal Construction Group, Inc. will replace magazines, Buildings 31126 and 31127, top of berm deteriorated substrait coatings and repair both magazines horizontal vent pipes.

SCOPE OF WORK:

Remove deteriorated protective coating, vegetation, and debris at top of each magazine.

Re-grade berm to original shape and compact top 6” soil to 95% maximum density.

Provide minimum 4” thick reinforced shotcrete over the berm.

Provide sealant around the vent pipe and between existing concrete wall and new shotcrete,

Repair horizontal vent pipes. Provide metal screen at horizontal vent pipe opening.

 

 

 